MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration
For quantitative PET information, correction of tissue photon attenuation is mandatory. Generally in conventional PET, the attenuation map is obtained from a transmission scan, which uses a rotating radionuclide source, or from the CT scan in a combined PET/CT scanner. In the case of PET/MRI scanners currently under development, insufficient space for the rotating source exists; the attenuation map can be calculated from the MR image instead. This task is challenging because MR intensities correlate with proton densities and tissue-relaxation properties, rather than with attenuation-related mass density. METHODS: We used a combination of local pattern recognition and atlas registration, which captures global variation of anatomy, to predict pseudo-CT images from a given MR image. These pseudo-CT images were then used for attenuation correction, as the process would be performed in a PET/CT scanner. RESULTS: For human brain scans, we show on a database of 17 MR/CT image pairs that our method reliably enables e stimation of a pseudo-CT image from the MR image alone. On additional datasets of MRI/PET/CT triplets of human brain scans, we compare MRI-based attenuation correction with CT-based correction. Our approach enables PET quantification with a mean error of 3.2% for predefined regions of interest, which we found to be clinically not significant. However, our method is not specific to brain imaging, and we show promising initial results on 1 whole-body animal dataset. CONCLUSION: This method allows reliable MRI-based attenuation correction for human brain scans. Further work is necessary to validate the method for whole-body imaging.
Author(s): | Hofmann, M. and Steinke, F. and Scheel, V. and Charpiat, G. and Farquhar, J. and Aschoff, P. and Brady, M. and Schölkopf, B. and Pichler, BJ. |
Journal: | Journal of Nuclear Medicine |
Volume: | 49 |
Number (issue): | 11 |
Pages: | 1875-1883 |
Year: | 2008 |
Month: | October |
Day: | 0 |
Bibtex Type: | Article (article) |
DOI: | 10.2967/jnumed.107.049353 |
Digital: | 0 |
Electronic Archiving: | grant_archive |
Language: | en |
Organization: | Max-Planck-Gesellschaft |
School: | Biologische Kybernetik |
Links: |
BibTex
@article{5592, title = {MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration}, journal = {Journal of Nuclear Medicine}, abstract = {For quantitative PET information, correction of tissue photon attenuation is mandatory. Generally in conventional PET, the attenuation map is obtained from a transmission scan, which uses a rotating radionuclide source, or from the CT scan in a combined PET/CT scanner. In the case of PET/MRI scanners currently under development, insufficient space for the rotating source exists; the attenuation map can be calculated from the MR image instead. This task is challenging because MR intensities correlate with proton densities and tissue-relaxation properties, rather than with attenuation-related mass density. METHODS: We used a combination of local pattern recognition and atlas registration, which captures global variation of anatomy, to predict pseudo-CT images from a given MR image. These pseudo-CT images were then used for attenuation correction, as the process would be performed in a PET/CT scanner. RESULTS: For human brain scans, we show on a database of 17 MR/CT image pairs that our method reliably enables e stimation of a pseudo-CT image from the MR image alone. On additional datasets of MRI/PET/CT triplets of human brain scans, we compare MRI-based attenuation correction with CT-based correction. Our approach enables PET quantification with a mean error of 3.2% for predefined regions of interest, which we found to be clinically not significant. However, our method is not specific to brain imaging, and we show promising initial results on 1 whole-body animal dataset. CONCLUSION: This method allows reliable MRI-based attenuation correction for human brain scans. Further work is necessary to validate the method for whole-body imaging.}, volume = {49}, number = {11}, pages = {1875-1883}, organization = {Max-Planck-Gesellschaft}, school = {Biologische Kybernetik}, month = oct, year = {2008}, slug = {5592}, author = {Hofmann, M. and Steinke, F. and Scheel, V. and Charpiat, G. and Farquhar, J. and Aschoff, P. and Brady, M. and Sch{\"o}lkopf, B. and Pichler, BJ.}, month_numeric = {10} }