B0 Shimming for in Vivo Magnetic Resonance Spectroscopy: Experts’Consensus Recommendations

{Magnetic resonance spectroscopy (MRS) and spectroscopic imaging (MRSI) allow the chemical analysis of physiological processes in vivo and provide powerful tools in the life sciences and for clinical diagnostics. Excellent homogeneity of the static B0 magnetic field over the object of interest is essential for achieving high-quality spectral results and quantitative metabolic measurements. The experimental minimization of B0 variation is performed in a process called B0 shimming. In this article, we summarize the concepts of B0 field shimming using spherical harmonic shimming techniques, specific strategies for B0 homogenization and crucial factors to consider for implementation and use in both brain and body. In addition, experts\textquotesingle recommendations are provided for minimum requirements for B0 shim hardware and evaluation criteria for the primary outcome of adequate B0 shimming for MRS and MRSI, such as the water spectroscopic linewidth.}

Author(s): Juchem, C and Cudalbu, C and de Graaf, RA and Gruetter, R and Henning, A and Hetherington, HP and Boer, VO
Journal: {NMR in Biomedicine}
Volume: 34
Number (issue): 5
Pages: 1--20
Year: 2021
Publisher: Heyden \& Son
Bibtex Type: Article (article)
DOI: 10.1002/nbm.4350
Address: London
Electronic Archiving: grant_archive

BibTex

@article{item_3240545,
  title = {{B0 Shimming for in Vivo Magnetic Resonance Spectroscopy: Experts\textquotesingle Consensus Recommendations}},
  journal = {{NMR in Biomedicine}},
  abstract = {{Magnetic resonance spectroscopy (MRS) and spectroscopic imaging (MRSI) allow the chemical analysis of physiological processes in vivo and provide powerful tools in the life sciences and for clinical diagnostics. Excellent homogeneity of the static B0 magnetic field over the object of interest is essential for achieving high-quality spectral results and quantitative metabolic measurements. The experimental minimization of B0 variation is performed in a process called B0 shimming. In this article, we summarize the concepts of B0 field shimming using spherical harmonic shimming techniques, specific strategies for B0 homogenization and crucial factors to consider for implementation and use in both brain and body. In addition, experts\textquotesingle recommendations are provided for minimum requirements for B0 shim hardware and evaluation criteria for the primary outcome of adequate B0 shimming for MRS and MRSI, such as the water spectroscopic linewidth.}},
  volume = {34},
  number = {5},
  pages = {1--20},
  publisher = {Heyden \& Son},
  address = {London},
  year = {2021},
  slug = {item_3240545},
  author = {Juchem, C and Cudalbu, C and de Graaf, RA and Gruetter, R and Henning, A and Hetherington, HP and Boer, VO}
}