Article 2021

The Traveling Heads 2.0: Multicenter Reproducibility of Quantitative Imaging Methods at 7 Tesla

{Object: This study evaluates inter-site and intra-site reproducibility at ten different 7 T sites for quantitative brain imaging. Material and methods: Two subjects - termed the "traveling heads" - were imaged at ten different 7 T sites with a harmonized quantitative brain MR imaging protocol. In conjunction with the system calibration, MP2RAGE, QSM, CEST and multi-parametric mapping/relaxometry were examined. Results: Quantitative measurements with MP2RAGE showed very high reproducibility across sites and subjects, and errors were in concordance with previous results and other field strengths. QSM had high inter-site reproducibility for relevant subcortical volumes. CEST imaging revealed systematic differences between the sites, but reproducibility was comparable to results in the literature. Relaxometry had also very high agreement between sites, but due to the high sensitivity, differences caused by different applications of the B1 calibration of the two RF coil types used were observed. Conclusion: Our results show that quantitative brain imaging can be performed with high reproducibility at 7 T and with similar reliability as found at 3 T for multicenter studies of the supratentorial brain.}

Author(s): Voelker, MN and Kraff, O and Goerke, S and Laun, FB and Hanspach, J and Pine, KJ and Ehses, P and Zaiss, M and Liebert, A and Straub, S and Eckstein, K and Robinson, S and Nagel, AN and Stefanescu, MR and Wollrab, A and Klix, S and Felder, J and Hock, M and Bosch, D and Weiskopf, N and Speck, O and Ladd, ME and Quick, HH
Journal: {NeuroImage}
Volume: 232
Pages: 1--14
Year: 2021
Publisher: Academic Press
Bibtex Type: Article (article)
DOI: 10.1016/j.neuroimage.2021.117910
Address: Orlando, FL
Electronic Archiving: grant_archive

BibTex

@article{item_3289708,
  title = {{The Traveling Heads 2.0: Multicenter Reproducibility of Quantitative Imaging Methods at 7 Tesla}},
  journal = {{NeuroImage}},
  abstract = {{Object: This study evaluates inter-site and intra-site reproducibility at ten different 7 T sites for quantitative brain imaging. Material and methods: Two subjects - termed the "traveling heads" - were imaged at ten different 7 T sites with a harmonized quantitative brain MR imaging protocol. In conjunction with the system calibration, MP2RAGE, QSM, CEST and multi-parametric mapping/relaxometry were examined. Results: Quantitative measurements with MP2RAGE showed very high reproducibility across sites and subjects, and errors were in concordance with previous results and other field strengths. QSM had high inter-site reproducibility for relevant subcortical volumes. CEST imaging revealed systematic differences between the sites, but reproducibility was comparable to results in the literature. Relaxometry had also very high agreement between sites, but due to the high sensitivity, differences caused by different applications of the B1 calibration of the two RF coil types used were observed. Conclusion: Our results show that quantitative brain imaging can be performed with high reproducibility at 7 T and with similar reliability as found at 3 T for multicenter studies of the supratentorial brain.}},
  volume = {232},
  pages = {1--14},
  publisher = {Academic Press},
  address = {Orlando, FL},
  year = {2021},
  slug = {item_3289708},
  author = {Voelker, MN and Kraff, O and Goerke, S and Laun, FB and Hanspach, J and Pine, KJ and Ehses, P and Zaiss, M and Liebert, A and Straub, S and Eckstein, K and Robinson, S and Nagel, AN and Stefanescu, MR and Wollrab, A and Klix, S and Felder, J and Hock, M and Bosch, D and Weiskopf, N and Speck, O and Ladd, ME and Quick, HH}
}