Miscellaneous 2018

The vascular fingerprint of non-balanced BOLD SSFP coherence pathways: gradient echoes show spin echo behavior

{The S2-SSFP echo (the echo before the RF pulse in non-balanced SSFP sequences, or F-0, PSIF, CE-FAST, T2-FFE) is a refocused echo and has thus been proposed for BOLD imaging to suppress larger vessels, similar to the classical spin echo. Here we demonstrate in Monte Carlo simulations that the primary S1-SSFP gradient echo shows nearly identical properties as the S2-SSFP echo. Both echoes of this non-balanced SSFP sequence can be used for BOLD imaging exhibiting a pure spin echo behavior, i.e suppression of larger vessels.}

Author(s): Scheffler, K and Baez-Yanez, M and Lohmann, G
Book Title: Joint Annual Meeting ISMRM-ESMRMB 2018
Year: 2018
Bibtex Type: Miscellaneous (misc)
Electronic Archiving: grant_archive

BibTex

@misc{SchefflerBL2018,
  title = {{The vascular fingerprint of non-balanced BOLD SSFP coherence pathways: gradient echoes show spin echo behavior}},
  booktitle = {{Joint Annual Meeting ISMRM-ESMRMB 2018}},
  abstract = {{The S2-SSFP echo (the echo before the RF pulse in non-balanced SSFP sequences, or F-0, PSIF, CE-FAST, T2-FFE) is a refocused echo and has thus been proposed for BOLD imaging to suppress larger vessels, similar to the classical spin echo. Here we demonstrate in Monte Carlo simulations that the primary S1-SSFP gradient echo shows nearly identical properties as the S2-SSFP echo. Both echoes of this non-balanced SSFP sequence can be used for BOLD imaging exhibiting a pure spin echo behavior, i.e suppression of larger vessels.}},