3D gradient echo snapshot CEST MRI with low power saturation for human studies at 3T

{Purpose For clinical implementation, a chemical exchange saturation transfer (CEST) imaging sequence must be fast, with high signal-to-noise ratio (SNR), 3D coverage, and produce robust contrast. However, spectrally selective CEST contrast requires dense sampling of the Z-spectrum, which increases scan duration. This article proposes a compromise: using a 3D snapshot gradient echo (GRE) readout with optimized CEST presaturation, sampling, and postprocessing, highly resolved Z-spectroscopy at 3T is made possible with 3D coverage at almost no extra time cost. Methods A 3D snapshot CEST sequence was optimized for low-power CEST MRI at 3T. Pulsed saturation was optimized for saturation power and saturation duration. Spectral sampling and postprocessing (B0 correction, denoising) was optimized for spectrally selective Lorentzian CEST effect extraction. Reproducibility was demonstrated in 3 healthy volunteers and feasibility was shown in 1 tumor patient. Results Low-power saturation was achieved by a train of 80 pulses of duration tp \textequals 20 ms (total saturation time tsat \textequals 3.2 seconds at 50\textpercent duty cycle) with B1 \textequals 0.6 $\mu$T at 54 irradiation frequency offsets. With the 3D snapshot CEST sequence, a 180 $\times$ 220 $\times$ 54 mm field of view was acquired in 7 seconds per offset. Spectrally selective CEST effects at +3.5 and \textendash3.5 ppm were quantified using multi-Lorentzian fitting. Reproducibility was high with an intersubject coefficient of variation below 10\textpercent in CEST contrasts. Amide and nuclear overhauser effect CEST effects showed similar correlations in tumor and necrosis as show in previous ultra-high field work. Conclusion A sophisticated CEST tool ready for clinical application was developed and tested for feasibility.}

Author(s): Deshmane, A and Zaiss, M and Lindig, T and Herz, K and Schuppert, M and Gandhi, C and Bender, B and Ernemann, U and Scheffler, K
Journal: {Magnetic Resonance in Medicine}
Volume: 81
Number (issue): 4
Pages: 2412--2423
Year: 2019
Publisher: Wiley-Liss
Bibtex Type: Article (article)
DOI: 10.1002/mrm.27569
Address: New York
Electronic Archiving: grant_archive

BibTex

@article{item_3009113,
  title = {{3D gradient echo snapshot CEST MRI with low power saturation for human studies at 3T}},
  journal = {{Magnetic Resonance in Medicine}},
  abstract = {{Purpose For clinical implementation, a chemical exchange saturation transfer (CEST) imaging sequence must be fast, with high signal-to-noise ratio (SNR), 3D coverage, and produce robust contrast. However, spectrally selective CEST contrast requires dense sampling of the Z-spectrum, which increases scan duration. This article proposes a compromise: using a 3D snapshot gradient echo (GRE) readout with optimized CEST presaturation, sampling, and postprocessing, highly resolved Z-spectroscopy at 3T is made possible with 3D coverage at almost no extra time cost. Methods A 3D snapshot CEST sequence was optimized for low-power CEST MRI at 3T. Pulsed saturation was optimized for saturation power and saturation duration. Spectral sampling and postprocessing (B0 correction, denoising) was optimized for spectrally selective Lorentzian CEST effect extraction. Reproducibility was demonstrated in 3 healthy volunteers and feasibility was shown in 1 tumor patient. Results Low-power saturation was achieved by a train of 80 pulses of duration tp \textequals 20 ms (total saturation time tsat \textequals 3.2 seconds at 50\textpercent duty cycle) with B1 \textequals 0.6 $\mu$T at 54 irradiation frequency offsets. With the 3D snapshot CEST sequence, a 180 $\times$ 220 $\times$ 54 mm field of view was acquired in 7 seconds per offset. Spectrally selective CEST effects at +3.5 and \textendash3.5 ppm were quantified using multi-Lorentzian fitting. Reproducibility was high with an intersubject coefficient of variation below 10\textpercent in CEST contrasts. Amide and nuclear overhauser effect CEST effects showed similar correlations in tumor and necrosis as show in previous ultra-high field work. Conclusion A sophisticated CEST tool ready for clinical application was developed and tested for feasibility.}},
  volume = {81},
  number = {4},
  pages = {2412--2423},
  publisher = {Wiley-Liss},
  address = {New York},
  year = {2019},
  slug = {item_3009113},
  author = {Deshmane, A and Zaiss, M and Lindig, T and Herz, K and Schuppert, M and Gandhi, C and Bender, B and Ernemann, U and Scheffler, K}
}